Enerji Test Servis LLC is an accredited body that carries out testing and reporting of electrical supply systems.
Inspection of power transmission lines
We conduct comprehensive inspections of power transmission lines using visual and modern diagnostic methods. This service aims to accurately pinpoint the location of damages on the lines and check the insulation condition, thereby increasing the reliability of power transmission.
Inspection of substations and electrical distribution units
We perform complex inspections to ensure the technical condition and safe operation of substation and distribution unit equipment. The service primarily includes periodic checks of the grounding system's effectiveness and the insulation condition of the equipment.
Inspection of transformers
To ensure the reliable and long-lasting operation of power transformers, we perform diagnostic tests of their main technical parameters. These tests check the transformation ratio, winding resistance, and insulation condition, allowing for the timely detection of potential failures.
Inspection of transformer oils
We check the quality and insulating properties of insulating oils used in transformers under laboratory conditions. The main goal is to determine the dielectric strength of the oil, ensuring it effectively performs its insulation function and protecting the equipment from internal breakdowns.
Relay protection and automation
We verify the operational capability and correctness of the parameters of relay protection and automation (RPA) devices in power systems. This service, particularly through periodic testing of functions like maximum current protection, ensures their error-free operation during faults, protecting equipment from serious damage.
Other Services
In addition to the mentioned services, our company also holds licenses for the installation of concrete and reinforced concrete structures, installation of metal structures, installation of wooden structures, facade works, and construction of engineering-communication networks.
Inspection of power transmission lines
Monitoring the technical condition of power transmission lines (PTL) is vital for the stable and uninterrupted transmission of electrical energy. Our company offers modern solutions for the comprehensive inspection of PTLs, ensuring the reliability and safety of your energy infrastructure. One of the main directions within this service is the precise determination of the location of potential or existing damages on the lines. By quickly identifying the location of faults that may arise due to adverse weather conditions, mechanical impacts, or aging, we facilitate the acceleration of repair work and minimize interruptions in energy supply.
Furthermore, we also provide periodic checking of the insulation resistance of the lines. The condition of insulators can deteriorate over time due to environmental factors (pollution, moisture) and operating conditions. Regular measurement of insulation resistance allows for the early detection of potential short-circuit risks and insulation breakdowns. As a result of these checks, the lifespan of the equipment is extended, the overall safety of the system is increased, and energy losses are prevented. With our professional team and modern equipment, we are ready to ensure the continuous and efficient operation of PTLs.

Inspection of substations and electrical distribution units
Substations and distribution units are critical nodes for managing the electrical network and efficiently distributing energy. To ensure the continuous and safe operation of these facilities, their regular and professional inspection is necessary. Our company offers a wide range of services for checking the technical condition of substations and distribution units. One of our main focuses is the periodic checking of the resistance of grounding systems installed in these facilities. Effective grounding is an important condition both for protecting personnel from electric shock and for preventing damage to equipment in cases such as short circuits and lightning strikes. Considering that the condition of the ground and contact connections changes over time, regular measurement of resistance ensures it remains within normative limits.
Another important inspection area is determining the insulation condition of equipment used in substations and distribution units (transformers, oil circuit breakers, disconnectors, cables, busbar systems, etc.). The insulation of equipment is the basis for its reliable and long-term operation. Service life, environmental conditions, and workload can cause insulation materials to age and lose their insulating properties. With modern diagnostic devices, we accurately assess the condition of the insulation, identifying weakened parts and potential failure risks in a timely manner. These checks help prevent equipment failures, accidents, and costly interruptions in energy supply.

Inspection of transformers
Transformers are essential elements of power transmission and distribution systems, regulating voltage levels. Regular technical diagnostics are crucial to ensure their reliable and long-term operation. Our company performs the following main checks as part of comprehensive transformer inspections:
Firstly, by determining the transformation ratio, we verify that the transformer accurately converts voltage to the required level. This parameter is essential for the system to operate in normal mode and for the correct setting of relay protection.
Secondly, through periodic inspection of winding resistance, we assess the integrity of the windings, the quality of internal connections, and the condition of the voltage regulator contacts (if present). This test helps identify potential sources of overheating and defects that could cause energy losses in a timely manner.
Thirdly, we determine the condition of the insulation, the most sensitive part of the transformer. Through insulation resistance and other specific tests, we ascertain its degree of moisture, contamination, and aging, thereby preventing internal short circuits and the potentially severe accidents that could result. These checks increase the reliability and service life of your transformers.

Inspection of transformer oils
Transformer oil is a crucial component in power transformers, serving both to provide effective insulation and to dissipate (cool) the heat generated by the active parts. For the oil to successfully perform these functions, its dielectric properties must remain at the required level. Over time and depending on operating conditions, moisture, various particles, or aging products can enter the oil, significantly reducing its insulating quality.
Therefore, an important part of our services is the periodic inspection of the dielectric permittivity of transformer oil, or more precisely, its dielectric strength (breakdown voltage). This check indicates the oil's resistance to electrical voltage, i.e., how well it performs its insulation function. A breakdown voltage below the specified norm indicates an increased risk of electrical discharges and short circuits within the transformer. Conducting this inspection in a timely manner allows for the early detection of potential failures, preventing transformer breakdowns and ensuring the reliability of the energy supply.

Relay protection and automation
Relay protection and automation (RPA) systems are complex devices designed to protect equipment from damage during short circuits, overloads, and other abnormal operating modes in power systems, and to ensure the stability of the network. Keeping these systems in constant working order is critically important for the reliability and safety of the power supply.
One of the main services we offer in this area is the periodic inspection of maximum current protection (MCP). Maximum current protection is one of the most fundamental types of protection that activates when it detects that the current flowing through the protected element exceeds a predetermined value, disconnecting the damaged part from the general network. During the inspection, parameters such as the pickup current and time delay of the MCP relays are checked, and the operational integrity of the relay itself and the breaker (circuit breaker) it activates is ensured. These periodic checks guarantee that the protection will operate correctly and reliably when truly needed, thus preventing costly equipment failures and long-term interruptions in the power supply.

Portfolio

★ AZERBAIJAN STATE YOUNG SPECTATORS THEATRE ★ "BAKU CRYSTAL HALL" LIMITED LIABILITY COMPANY ★ "EKOL ENGINEERING SERVICES" CLOSED JOINT-STOCK COMPANY ★ POLICE ACADEMY OF THE MINISTRY OF INTERNAL AFFAIRS OF THE REPUBLIC OF AZERBAIJAN ★ "DEBET SAFETY" LIMITED LIABILITY COMPANY ★ REPRESENTATIVE OFFICE OF "BAHAR ENERGY OPERATING COMPANY LIMITED" IN THE REPUBLIC OF AZERBAIJAN ★ "RRM REPAIR-CONSTRUCTION" CLOSED JOINT-STOCK COMPANY ★ "AZERBAIJAN INTERNATIONAL TELECOM (AZINTELECOM)" LIMITED LIABILITY COMPANY ★ "AZERTERMINALKOMPLEKS" UNION OF THE STATE CUSTOMS COMMITTEE OF THE REPUBLIC OF AZERBAIJAN ★ "INSHAAT REPAIR-CONSTRUCTION PRODUCTION UNION (TTIB)" LIMITED LIABILITY COMPANY ★ "CENUBTIKINTISERVIS" OPEN JOINT-STOCK COMPANY ★ "ATENA" LIMITED LIABILITY COMPANY ★ "ABSHERON MAKINA" LIMITED LIABILITY COMPANY ★ "ZIRAAT BANK AZERBAIJAN" OPEN JOINT-STOCK COMPANY ★ "QARDASHLAR-M" LIMITED LIABILITY COMPANY ★ "GARAGE PARKING" LIMITED LIABILITY COMPANY ★ AZERBAIJAN FOOD SAFETY INSTITUTE PUBLIC LEGAL ENTITY ★ "ELBERG" Limited Liability Company ★ "IS CONSUMER PRODUCTS" LIMITED LIABILITY COMPANY ★ "ELIT-S" LIMITED LIABILITY COMPANY ★ REPRESENTATIVE OFFICE OF GRUP FLORENCE NIGHTINGALE HASTANELERİ ANONİM ŞİRKETİ IN THE REPUBLIC OF AZERBAIJAN ★ "PJA" LIMITED LIABILITY COMPANY ★ "BAKU INTERNATIONAL TOBACCO" LIMITED LIABILITY COMPANY ★ "AZERTERMINALKOMPLEKS" UNION OF THE STATE CUSTOMS COMMITTEE OF THE REPUBLIC OF AZERBAIJAN ★ “NOBEL FOOD INDUSTRY” LIMITED LIABILITY COMPANY ★ "TEXNOLAND" Limited Liability Company ★ "BAKU SPORTS PALACE" LIMITED LIABILITY COMPANY ★ "PROS RETAIL AZ" LIMITED LIABILITY COMPANY ★ "BEST BRANDS GROUP MA" LIMITED LIABILITY COMPANY ★ "SSI RETAIL" LIMITED LIABILITY COMPANY ★ "FBCO" LIMITED LIABILITY COMPANY ★ "BISQUE LLC" LIMITED LIABILITY COMPANY ★ "AYMA ALYANS" LIMITED LIABILITY COMPANY ★ "SINTEKS" LIMITED LIABILITY COMPANY ★ "HAZEL CHOCOLATE" Limited Liability Company ★ "KHazar UNIVERSITY DUNYA SCHOOL" LIMITED LIABILITY COMPANY ★ "IMPROTEX INDUSTRIES" LIMITED LIABILITY COMPANY ★ "N.T.D" Limited Liability Company ★ NASIMI DISTRICT HYGIENE AND EPIDEMIOLOGY CENTER ★ "AZBETON INSHAAT-S" LIMITED LIABILITY COMPANY ★ "PROS RETAIL AZ" LIMITED LIABILITY COMPANY ★ "BOS SHELF" LIMITED LIABILITY COMPANY ★ "SHIKH" SANATORIUM OF KURORT JOINT-STOCK COMPANY ★ "AZERBAIJAN RAILWAYS" CLOSED JOINT-STOCK COMPANY ★ "METANET-A" COMPANY ★ "LANSET-SURGICAL CLINIC" LIMITED LIABILITY COMPANY ★ "AZVIRT" LIMITED LIABILITY COMPANY ★ "MELHEM INTERNATIONAL HOSPITAL" Limited Liability Company ★ "ADORE COMPANY" LIMITED LIABILITY COMPANY ★ "INNOVA CONSTRUCTION AND CONTRACTING" LIMITED LIABILITY COMPANY ★